• Monday - Friday: 8:30 - 17:00 Saturday - Sunday: Closed
  • Avon Marina, Rossiters Quay, Christchurch, Dorset BH23 1DZ
  • 01202 612610

Northern Lights Marine Generator 12/10KW

Northern Lights Marine Generator 12/10KW

For more information or to place an order, please contact us by calling 01202 612 610 or email info@avonmarina.com

Description

Features and Benefits

Engine Block Four cycle, 3 cylinder, liquid cooled, naturally aspirated, overhead valve diesel with glow plugs for quick starting. Swirl combustion chambers improve fuel efficiency and reduce smoke.
Cooling System Standard heat exchanger cooling with optional keel cooling. Copper-nickel, tubetype heat exchanger has removable rubber end caps for easy cleaning, and no need for zincs. The bronze and stainless steel seawater pump with rubber impeller is gear driven, eliminating a potential failure point.
Fuel System The self-venting fuel system features an inline injection pump with 3-5% mechanical governor for close AC frequency control. Stop solenoid acts directly on the fuel rack eliminating external linkage problems. The fuel lift pump is mechanical with a hand primer, eliminating electronic pump failures.
Intake and Exhaust The M843NW3G meets US EPA Tier III at 60 Hz and IMO Tier II at 50 Hz emission standards. Its cast aluminum intake manifold with Sound Maze system reduces noise, and its washable air cleaner makes routine maintenance simple. The wet exhaust elbow is stainless steel.
Lubrication System The closed crankcase vent system traps oil vapor and keeps engine room clean. 4.2 qt (4.0 ltr) oil capacity for better lubrication and 200 hour oil change intervals. Oil drain hose with valve plumbed to base pan as standard.
DC Electrical System The DC System features a 12 volt starter motor and battery charging alternator with belt guard. The set is equipped with a standard remote mount control panel, featuring an hour meter, stop-start switch with run light and a preheat switch, and includes a 20 foot (6m) harness. The standard panel can be expanded to six panels, up to 110 feet from the set. Low oil pressure, high coolant temperature and high exhaust temperature safety shutdowns are standard.
AC Generator The Northern Lights, direct coupled, four pole, four lead generator has Class “H insulation, a pre-lubricated bearing and features a conservative heat rise rating of 95°C/50°C ambient. Our automatic voltage regulator gives you ±1% voltage regulation. The AVR protected by a dedicated circuit breaker.
Additional Options Ignition Protected Option. Tested to meet criteria for outboard engine boats.

 

Product Specifications

AC Output
12 KW 60 Hz, 1800 RPM, 1 Ph, 1.0 PF,
240 V/50 A, 120 V/100 A
10 KW 50 Hz, 1500 RPM, 1 Ph, 1.0 PF,
220 V/45.4 A
Optional Three Phase with 0.8 PF
Voltage regulation ±1%

Based on SAE J1995 and ISO 3046.

Weight and Height
Approximate dry weight 736 lbs (344 kg)
Length 38.5 in (978 mm)
Width 19.0 in (483 mm)
Height 25.3 in (643 mm)
Sound enclosure weight 53 lbs (24 kg)
Enclosure length 38.8 in (986 mm)
Enclosure width 22.5 in (574 mm)
Enclosure height 25.8 in (655 mm)

Engine Data
Type Vertical inline 3 cylinder diesel
Displacement 91 in3 (1.5 ltr)
Bore/Stroke 3.30/3.50 in (84/90 mm)
HP @ RPM 20/1800 17/1500
Approximate fuel use:
1800 RPM @ full load 1.20 gph (4.50 lph)
1800 RPM @ half load 0.62 gph (2.30 lph)
1500 RPM @ full load 1.00 gph (3.78 lph)
1500 RPM @ half load 0.51 gph (1.93 lph)

Actual fuel consumption will vary depending on operating conditions.

Installation Data
Wet exhaust elbow 2 inch (51 mm) OD
Raw water inlet 3/4 in (19 mm) OD
Fuel inlet 1/4 – NPT
Fuel return 1/4 – NPT

Information and dimensions are subject to change without notice.

 